Nano2 Brick Fast Acting Surface Mounted Fuse is a very small, Wire-in-Air (WIA) square shape surface mount fuse which is very suitable for the secondary side circuit over-current protection applications and is designed for PCB using surface mount technology.
4512 1245 Nano2 Brick Square End Block Fast Acting Surface Mount Fuse 50A 250VAC
Applications Of Nano2 Brick Fast Acting Surface Mounted Fuse
Notebook PCLCD/PDP TVLCD monitorLCD/PDP panelLCD backlight inverterPortable DVD playerPower supplyNetworkingPC serverCooling fan systemStorage systemTelecom systemWireless basestationWhite goodsGame consoleOffice Automation equipmentBattery charging circuit protectionIndustrial equipment
Features Of Nano2 Brick Fast Acting Surface Mounted Fuse
· Fast Acting High current brick fuse
· Surfacemount deign tosave space
· Wide range of current rating available
· Wide operating temperature range
· Low temperature rerating
· Designed to UL248-1/14
· Ceramic Suqare bodywith end capdesign
Electrical Characteristics Of Nano2 Brick Fast Acting Surface Mounted Fuse
Ampere |
100% In |
250%In |
350%In |
15A-20A-50A |
4 Hour Min |
<10s |
- |
60A-100A |
4 Hour Min |
- |
<10s |
Dimension Of Nano2 Brick Fast Acting Surface Mounted Fuse (mm)
Series |
Rated Current |
L |
W |
H |
R1032 |
15A-30A |
10.0±0.30 |
1.7±0.10 |
3.15±0.10 |
1245/4512 |
40A-100A |
12.30±0.40 |
2.70±0.20 |
4.50±0.20 |
Recommended Pad Layout Of Nano2 Brick Fast Acting Surface Mounted Fuse
15A-30A: Recommend trace thickness is 3oz; the minimum trace width is 10mm
40A-50A: Recommend trace thickness is 3oz; the minimum trace width is 15mm
60A-70A: Recommend trace thickness is 3oz; the minimum trace width is 22mm
80A-100A: Recommend trace thickness is 6oz; the minimum trace width is 33mm
Specification Of Nano2 Brick Fast Acting Surface Mounted Fuse
P/N |
Rated Voltage (V) |
Rated Current |
Breaking Capacity |
Typ. Cold Resistance
|
Typical Voltage Drop |
Typical Pre-Arcing I2t |
||
- |
VAC |
VDC |
(A) |
AC1 |
DC2 |
mΩ |
mV |
(A2Sec)3 |
R1032.10A |
125V 250V |
250V 125V 80V 72V 60V 32V |
10 |
250Vac,150A 125Vac,150A |
800A |
2.90 |
105 |
10 |
R1032.15A |
15 |
2.90 |
105 |
15 |
||||
R1032.20A |
20 |
2.90 |
105 |
20 |
||||
R1032.25A |
25 |
1.50 |
100 |
70 |
||||
R1032.30A |
30 |
N/A |
1.10 |
100 |
95 |
|||
R1032.40A |
40 |
1.10 |
100 |
280 |
||||
1245.40 |
250V 125V 80V 72V 63V 32V |
40 |
250Vac,300A 125Vac,500A |
1000A |
1.10 |
100 |
280 |
|
1245.50 |
125V |
50 |
125Vac,500A |
0.95 |
105 |
480 |
||
1245.60 |
60 |
0.60 |
75 |
900 |
||||
1245.80 |
80 |
0.44 |
65 |
1700 |
||||
1245.100 |
100 |
0.29 |
55 |
5000 |
1. AC Interrupting Rating (Measured at designated voltage, 100% power factor random closing)
2. DC Interrupting Rating (Measured at designated voltage, time constant of less than 50 microseconds,battery source)
3. Typical Pre-arcing I2t are measured at 10In Current, DC battery bank, but not exceeding the interruptingrating, time constant of calibrated circuit less than 50 microseconds)
4. Internal qualification for 40A-60A @ 80Vdc, UL Approval is pending
Soldering Characteristics Of Nano2 Brick Fast Acting Surface Mounted Fuse
Reflow Soldering
• Temperature: 260° C
• Time: 30 Seconds Maximum
Selection Factors Of Nano2 Brick Fast Acting Surface Mounted Fuse
1. Normal operating current
2. Application voltage (AC or DC)
3. Ambient temperature
4. Overload current and length of time in which the fuse must open
5. Maximum available fault current
6. Pulses, Surge Currents, Inrush Currents, Start-up Currents, and Circuit Transients
7. Physical size limitations, such as length, diameter, or height
8. Agency Approvals required, such as UL, CSA, VDE, METI, MITI or Military
9. Fuse features (mounting type/form factor, ease of removal, axial leads, visual indication, etc.)
10. Fuse holder features, if applicable and associated rerating (clips, mounting block, panel mount, PC board mount, R.F.I. shielded, etc.)
11. Application testing and verification prior to production
Time-Current Curves Of Nano2 Brick Fast Acting Surface Mounted Fuse
Temperature derating curve Of Nano2 Brick Fast Acting Surface Mounted Fuse
● Normal Operating Temperature: 25℃± 2℃
● Operating Temperature: -55℃ to 125℃ with proper correction factor applied.
● Chart of correction factor
Package and Minimum order QTY Of Nano2 Brick Fast Acting Surface Mounted Fuse
15-20A-30A: 2000pcs fuses in tape (width 24mm) and reel (dia. 13inch);
40A-100A: 1000pcs fuses in tape (width 24mm) and reel (dia. 13inch)